The 392 series is an industry standard “octal” base version of DC sensitive relay. Single pole versions operate on as little as 125mW and are capable of switching 5 amps. Power requirements increase by 125mW per pole up to 3 poles. Operating current can be as low as 11.1mA. The 392 series can withstand wide voltage ranges of up to almost 4X minimum voltage without overheating. Single pole and double pole versions have 8 pin bases. The 3 pole version has 11 pins. All are intended for socket mounting.
Additional contact configurations and coil options are available – please use the RFQ/RFI tab above to submit your request.
Additional contact configurations and coil options are available – please use the RFQ/RFI tab above to submit your request.
Unit of Measure
Specifications
|
Contacts
|
Coil
|
Timing
|
Dielectric Strength
|
Temperature
|
Life Expectancy
|
Miscellaneous Characteristics
Specifications
Series |
N/A 392 |
Contact Arrangement |
N/A XAX (SPDT) - (1 form C) |
Construction |
N/A Enclosed plug-in |
Options |
N/A Manual actuator |
Coil Current |
N/A 11.1 MA/DC |
Contacts
Contact Configuration |
N/A Up to 3PDT |
Contact Material |
N/A Silver |
Contact Rating |
N/A 5 A |
Contact Rating 120 / 240VAC Resistive |
N/A 5 A |
Contact Rating 28VDC Resistive |
N/A 5 A |
Contact Resistance, Initial |
N/A 100 milliohms max at 6VDC |
Coil
Coils Available |
N/A AC and DC |
Minimum Coil Power-Single Pole |
N/A 125 mW |
Minimum Coil Power-Double Pole |
N/A 250 mW |
Minimum Coil Power-3 Pole |
N/A 375 mW |
Duty |
N/A Continuous |