You can also search for a Competitor Cross Reference to find a drop-in equivalent 88H Series relay.
Contact Transfer LED Indicator
LED is not wired to coil like traditional relays, providing positive confirmation of contact transfer unlike legacy hermetically sealed relays.
Hermetically Sealed Construction
The inert, dry nitrogen environment mitigates corrosion and/or oxidation of the internal relay components including the contacts.
Coil
Coil Temperature Rating 155 °C (Class F) Optional coil suppression diode that will protect your sensitive equipment from coil transient voltage.
Corrosion Resistant
Contact Transfer LED Indicator
LED is not wired to coil like traditional relays, providing positive confirmation of contact transfer unlike legacy hermetically sealed relays.
Hermetically Sealed Construction
The inert, dry nitrogen environment mitigates corrosion and/or oxidation of the internal relay components including the contacts.
Coil
Coil Temperature Rating 155 °C (Class F) Optional coil suppression diode that will protect your sensitive equipment from coil transient voltage.
Corrosion Resistant
- Nickel Plated Brass Cover
- Salt water Resistant
Unit of Measure
Specifications
|
Contacts
|
Coil
|
Timing
|
Dielectric Strength
|
Temperature
|
Life Expectancy
|
Miscellaneous
Specifications
Industry Standards/Certifications |
N/A UL/CUL Listed for ordinary locations (E52197) and Class I, Div 2 hazardous locations (E509225) with Approved Sockets SK-CIR8-DS or SK-CIR11-DS (E340027). |
Type |
N/A Hermetically Sealed Relay |
Series |
N/A 88H |
Maximum Switching Voltage |
N/A 240VAC/30VDC |
Mounting Type |
N/A 8 Pin Octal Socket Mount |
Coil Resistance |
N/A 72 Ω |
Contacts
Contact Configuration |
N/A DPDT, 2FormC |
Contact Material |
N/A Silver Alloy |
Contact Rating |
N/A 12 A |
Thermal (Carrying) Current |
N/A 12 A |
Coil
AC Coil Voltage |
N/A 24 V |
Average Consumption Coil |
N/A 2.1 VA |
Maximum Operating Voltage |
N/A 110 % |
Drop-out Voltage |
N/A Minimum 10% of nominal VAC |
Maximum Pickup Voltage |
N/A 85% of nominal |
Dielectric Strength
Dielectric Strength (Across Open Contacts) |
N/A 1000 Vrms |
Dielectric Strength (Between Parts of Opposite Polarity) |
N/A 1500 Vrms |
Temperature
Operating Temperature [Min] |
N/A -20 ºC |
Operating Temperature [Max] |
N/A 40 ºC |
Ambient Temperature - Storage |
N/A -40 to +85 ºC |
Temperature Code for Hazardous Locations |
N/A T4A: +40 ºC (+104 ºF) |