Versatile. Rugged. Proven. These are but a few words used by customers to describe the 219 series. When long life and cost of down time / service are important the 219 solves the problem. It’s a standard throughout industrial applications which many other relays are measured against. Capable of up to four poles double throw or six poles single throw. Contact arrangements are easily customized for special applications. NUCLEAR versions available.

The nuclear version of the 219 relay is made in the USA with some special materials and they are qualified by Wyle Laboratories to the following standards:

IEEE Standard 323-1974 "IEEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations"
IEEE Standard 344-1975 "IEEE Recommended Practices for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations"

Configure Your Series 219 Relay below. Select the contact combination and other options you need for your application.
UL Recognized, UL Listed, & CSA                   Made in U.S.A. Models Available

Modify Configuration

Instructions
Series
Contact Type
Contact Combination

AAX
(SPST-NO & SPDT)
(1 Form A & 1 Form C)

ABA
(SPST-NO, DPDT, SPST-NC)
(1 Form A, 2 Form C & 1 Form B)

ABB
(SPST-NO, DPDT, DPST-NC)
(1 Form A, 2 Form C & 2 Form B)

ABX
(SPST-NO & DPDT)
(1 Form A & 2 Form C)

AXE
(SPST-NO & 5PST-NC)
(1 Form A & 5 Form B)

BBX
(DPST-NO & DPDT)
(2 Form A & 2 Form C)

BXB
(DPST-NO & DPST-NC)
(2 Form A & 2 Form B)

BXC
(DPST-NO & 3PST-NC)
(2 Form A and 3 Form B)

BXD
(DPST-NO & 4PST-NC)
(2 Form A & 4 Form B)

CBX
(3PST-NO & DPDT)
(3 Form A & 2 Form C)

CXB
(3PST-NO & DPST-NC)
(3 Form A & 2 Form B)

CXC
(3PST-NO & 3PST-NC)
(3 Form A & 3 Form B)

DAX
(4PST-NO & SPDT)
(4 Form A & 1 Form C)

DXB
(4PST-NO & DPST-NC)
(4 Form A & 2 Form B)

DXX
(4PST-NO)
(4 Form A)

EXA
(5PST-NO & SPST-NC)
(5 From A & 1 Form B)

EXX
(5PST-NO)
(5 Form A)

FXX
(6PST-NO)
(6 Form A)

HXH
(SPST-NO-DM & SPST-NC-DB)
(1 Form X & 1 Form Y)

HXJ
(SPST-NO-DM & DPST- NC-DB)
(1 Form X & 2 Form Y)

HXX
(SPST-NO-DM)
(1 Form X) 

JXH
(DPST-NO-DM & SPST-NC-DB)
(2 Form X & 1 Form Y)

JXX
(SPST-NO-DM)
(2 FormX)

KXX
(3PST-NO-DM)
(3 Form X)

XAX
(SPDT)
(1 Form C)

XBB
(DPDT, DPST-NC)
(2 Form C & 2 Form B)

XBX
(DPDT)
(2 Form C)

XCX
(3PDT)
(3 Form C)

XDX
(4PDT)
(4 Form C)

XHX
(SPDT-DM-DB)
(Form Z)

XJX
(DPDT-DM-DB)
(2 Form Z)

XXD
(4PST-NC)
(4 Form Y)

XXF
(6PST-NC)
(6 Form B)

XXH
(SPST-NC-DB)
(Form Y)

XXJ
(DPST-NC-DB)
(2 Form Y)

XXK
(3PST-NC-DB)
(3 Form Y)
Contact Combination Note
Corresponding Socket PN
Enclosure
Other Option
  • Blowout Magnet - For use with contact loads in excess of 40VDC(Code "69")
  • Coil Arc Suppressor & Snubber Network (Code 'V1' for VAC Coils)
  • Coil Suppression Diode - (Code 'V' for VDC Coils)
  • Cover Gasket – Neoprene Rubber (Code "N")
  • LED Indicator - (Code "L")
  • Manual Actuator - (Code "M")
Bifurcated Contacts UL-Rated (5A@ 120VAC or 2.5A @240VAC) 1
No Yes
Coil Voltage
Contact Rating
Contact Rating Note
  • 1 For use with switching low level current below 50mA
    See Data Sheet for UL and additional contact ratings