The 112 series relays are capable of sensing extremely low current flow. They are frequently used to detect ground faults or in applications where applied voltage varies significantly. DC versions can sense currents as low as 0.61mA and tolerate voltages up to 10X minimum. AC versions can sense currents as low as 0.74mA and can tolerate voltages up to 5X minimum. Single pole DC coil versions use as little as 12mW of power while double pole versions can be as low as 60mW. Single pole AC coil version use as little as 160mVA while double pole versions can be as low as 800mVA. Pick-up or drop-out current can be fine tuned by end user via knurled thumbwheel after loosening locknut. Remove all power to make adjustments.

Additional contact configurations and coil options are available – please use the RFQ/RFI tab above to submit your request.
CSA               Made in U.S.A.
Unit of Measure
Items
112 Series - Low Coil Power Sensitive Relays - Industrial Pin Out

112 Series - Low Coil Power Sensitive Relays - Industrial Pin Out

112 Series - Low Coil Power Sensitive Relays - Industrial Pin Out

112 Series - Low Coil Power Sensitive Relays - Industrial Pin Out

112 Series - Low Coil Power Sensitive Relays - Industrial Pin Out

112 Series - Low Coil Power Sensitive Relays - Industrial Pin Out

112 Series - Low Coil Power Sensitive Relays - Industrial Pin Out

112 Series - Low Coil Power Sensitive Relays - Industrial Pin Out

112 Series - Low Coil Power Sensitive Relays - Industrial Pin Out

112 Series - Low Coil Power Sensitive Relays - Industrial Pin Out
Series N/A 112
Contact Arrangement N/A XAX (SPDT) - (1 form C)
Construction N/A Panel Mount
Coil Current N/A 0.61mA DC N/A 1.58mA DC N/A 1.84mA DC N/A 3.85mA AC N/A 6.0mA AC
Contact Configuration N/A SPDT, DPDT
Contact Material N/A Silver
Contact Rating N/A 2 A
Contact Rating 120 / 240VAC Resistive N/A 2 A
Contact Rating 28VDC Resistive N/A 2 A
Contact Resistance, Initial N/A 100 milliohms max at 6VDC
Coils Available N/A AC and DC
Minimum Coil Power-Single Pole N/A 160 mVA
Minimum Coil Power-Double Pole N/A 800 mVA
Duty N/A Continuous
Operate Time (max) N/A 20 ms
Release Time (max) N/A 20 ms
Across Open Contacts N/A 500 Vrms
Between Mutually Insulated Point N/A 1500 Vrms
Insulation Resistance N/A 1,000 Mohms min at 500VDC
Operating N/A -20 to 60 ºC-4 to 140 ºF
Storage N/A -40 TO 105 ºC-40 to 221 ºF
Electrical (full load) N/A 100,000
Mechanical (no load) N/A 500,000
Mounting Position N/A any
Mating Socket N/A 27390D (P or PGF versions)
Weight N/A 7.5 oz241 g