The 236 series voltage sensor combines solid state sensing circuitry with a SPDT 13 amp relay or a DPDT 10 amp relay. The single pole version has recessed potentiometers for adjustment.The double pole version has knob adjustments. Pull-in voltage is 75 to 115% of nominal voltage. Dropout is 75 to 95% of set pick up.
Applications: Brownout protection, warning of under voltage condidtions and over voltage protection.
Prevents equipment burn out
Additional contact configurations and coil options are available – please use the RFQ/RFI tab above to submit your request.
Applications: Brownout protection, warning of under voltage condidtions and over voltage protection.
Prevents equipment burn out
Additional contact configurations and coil options are available – please use the RFQ/RFI tab above to submit your request.
Unit of Measure
Specifications
|
Contacts
|
Coil
|
Dielectric Strength
|
Temperature
|
Life Expectancy
|
Miscellaneous
Contacts
Contact Configuration |
N/A SPDT |
Contact Material |
N/A Silver Alloy |
Contact Rating |
N/A SP =13 A / 13 A DP = 10 A /10 A |
Contact Rating 120 / 240VAC Resistive |
N/A 10 A |
Contact Rating 28VDC Resistive |
N/A SP = 13 Amp DP = 10 Amp |
Contact Rating Motor 120VAC |
N/A 1/3 hp |
Contact Rating Motor 240VAC |
N/A 1/2 hp |
Minimum Contact Load |
N/A 500 mW |
Contact Resistance, Initial |
N/A 100 milliohms max at 6VDC |
Coil
Coils Available |
N/A AC and DC |
Power Consumption |
N/A 3.5 VA |
Input Voltage Absolute Maximum |
N/A Lowest of +60% of nominal or 600VAC |
Pickup Voltage Range |
N/A 75% to 115% of nominal |
Dropout Voltage Range |
N/A 75% to 95% of set pickup |
Transient Protection |
N/A Yes |
Duty |
N/A Continous |
Dielectric Strength
Across Open Contacts |
N/A 500 Vrms |
Between Mutually Insulated Point |
N/A 1.500 Vrms |
Insulation Resistance |
N/A 1,000 Mohms min at 500VDC |