575 Series - Motor Reversing Contactors
Motor Relays
The 575 series relay is rated to 7.5HP. Two sets of 3 pole, double-make, N.O. contacts are mechanically interlocked to prevent simultaneous closure. Front mounted auxiliary contacts are available for electrical lockup. The 575 motor revering contactor is widely used for control of overhead doors, elevators, hoists, machine tools, and others similar devices that requires frequent jogging.
Additional contact configurations and coil options are available – please use the RFQ/RFI tab above to submit your request.
Made in U.S.A.
Additional contact configurations and coil options are available – please use the RFQ/RFI tab above to submit your request.
Made in U.S.A.
Unit of Measure
Items |
/Asset/575_Series.JPG A575KXX-24VAC 575 Series - Motor Reversing Contactors |
/Asset/575_Series.JPG A575KXX-120VAC 575 Series - Motor Reversing Contactors |
/Asset/575_Series.JPG A575KXX-240VAC 575 Series - Motor Reversing Contactors |
/Asset/575_Series.JPG A575KXX-12VDC 575 Series - Motor Reversing Contactors |
/Asset/575_Series.JPG A575KXX-24VDC 575 Series - Motor Reversing Contactors |
|||||
Series | N/A 575 | |||||||||
Contact Arrangement | N/A KXX (2X 3PST – N.O. – double make) | |||||||||
Optional Features | N/A | |||||||||
Coil Voltage | N/A 24 VAC | N/A 120 VAC | N/A 240 VAC | N/A 12 VDC | N/A 24 VDC | |||||
Contact Configuration | N/A 3PST-NO Double Make per side | |||||||||
Contact Material | N/A Silver Alloy | |||||||||
Contact Rating | N/A 30 A | |||||||||
Contact Rating 120 / 240VAC Resistive | N/A 30 A | |||||||||
Motor 120VAC 1 Phase | N/A 1.5 hp | |||||||||
Motor 240VAC 1 Phase | N/A 3 hp | |||||||||
Motor 240VAC 2-3 Phase | N/A 5 hp | |||||||||
Motor 480 / 600VAC 2-3 Phase | N/A 7.5 hp | |||||||||
Contact Resistance, Initial | N/A 100 milliohms max at 6VDC | |||||||||
Coils Available | N/A AC and DC | |||||||||
Nominal Coil Power AC | N/A 22 VA | |||||||||
Nominal Coil Power DC | N/A 10 W | |||||||||
Input Voltage Tolerance - AC | N/A 85% to 110% of nominal | |||||||||
Input Voltage Tolerance - DC | N/A 80% to 110% of nominal | |||||||||
Drop-out voltge | N/A 10% of nominal | |||||||||
Duty | N/A Continuous | |||||||||
Operate Time (max) | N/A 60 ms | |||||||||
Release Time (max) | N/A 30 ms | |||||||||
Across Open Contacts | N/A 2500 Vrms | |||||||||
Between Mutually Insulated Point | N/A 2500 Vrms | |||||||||
Insulation Resistance | N/A 1000 megohms at 500VDC | |||||||||
Operating | N/A -34 to 74 ºC-30 to 165 ºF | |||||||||
Storage | N/A -40 TO 105 ºC-40 to 221 ºF | |||||||||
Electrical (full load) | N/A 100,000 | |||||||||
Mechanical (no load) | N/A 1,000,000 | |||||||||
Mounting Position | N/A Vertical , Contacts Up | |||||||||
Enclosure | N/A Semi-Enclosed | |||||||||
Weight | N/A 42.0 oz1100 g | |||||||||
|